To prevent any leakage and to ensure pressure integrity of the metal-to-metal seal connections, the minimum make-up torque requirement has been increased to 50% of its tool joint torsional strength. The maximum make up torque is still calculated based on 60% of tool joint torsional strength.
The following metal-to-metal seal connections are affected:
Ø XTM-39
Ø XTM-40
Ø XTM-46
Ø CTM-46
Ø CTM-57
|